201-xxx-DPDT Series – Three-Phase Voltage/Phase Monitor Series - Littelfuse 201-xxx-DPDT Voltage Monitoring Relays Provide Superior Protection

201 SP DPDT
Roll Over to Zoom
Disclaimer Notice

Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The 201-xxx-DPDT series is an 11-pin octal base, plug-in voltage monitor designed to protect three-phase motors regardless of size. The 201-100-DPDT is used on 95–120 V ac, 50/60 Hz motors to prevent damage caused by low voltage. The 201-200-DPDT is used on 190–240 V ac, 50/60 Hz motors to prevent damage caused by incoming voltage problems. These monitors feature two isolated sets of contacts that are ideal for use with two control circuits with different voltages. The unique microcontroller-based voltage and voltage-sensing circuit constantly monitors the voltage to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s output relays are deactivated after a specified trip delay. The output relays reactivate after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions.

This unit is also available with a shorter trip delay and faster restart delay. The 201-xxx-DPDT-60mS has a trip delay of 0.5 seconds and a restart delay of 60 milliseconds.

Notes:
Must use Model OT11PC socket for UL Rating.
Manufacturer’s recommended screw terminal torque for the RB series and OT series octal sockets is 12 in.-lbs.

Features

  • Proprietary microcontroller-based circuitry
  • Two isolated Form C relays (DPDT)
  • Advanced LED diagnostics
  • Compact design for 11-pin, DIN-rail or surface mounted

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)HumidityInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Restart Delay RangeTrip Delay RangeTrip Point Accuracy (%)Undervoltage Reset Voltage (%)Undervoltage Trip VoltageStockSamplesCompare
201-100-DPDT95 - 120 VacDPDTTorque: 12 in-lbs.; 12 - 22 AWG solid or strandedDIN rail or surface mount (plug-in to OT11-PC socket)1.75 H x 2.38 W x 4.13 D in. (44.5 x 60.3 x 104.8 mm)0 Kg95% non-condensing per IEC 68-2-350 / 605Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacAfter a Fault or Complete Power Loss: 2 sLow Voltage: 4 s; Unbalance/Phase faults: 2 s±1%93%90%CheckOrder
201-200-DPDT190 - 240 VacDPDTTorque: 12 in-lbs.; 12 - 22 AWG solid or strandedDIN rail or surface mount (plug-in to OT11-PC socket)1.75 H x 2.38 W x 4.13 D in. (44.5 x 60.3 x 104.8 mm)0 Kg95% non-condensing per IEC 68-2-350 / 605Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacAfter a Fault or Complete Power Loss: 2 sLow Voltage: 4 s; Unbalance/Phase faults: 2 s±1%93%90%CheckOrder
To request product environmental information, please complete the Product Environmental Information Request Form.