The 460 Series Slo-Blo® SMF is based on Littelfuse PICO® fuse through-hole technology, though offered in a surface mount package.
This series of devices meets the requirements of the RoHS directive.
This series of devices meets the requirements of the RoHS directive.
- Slow-Blow
- High inrush current withstand capability
- Wide range of current ratings from 375 mA to 5 A
- Wide operating temperature range
- RoHS compliant
460 Parts
Filters
Showing 1 to 11 of 11 Total Results
Part Number | Actions | Maximum AC Voltage (V) | Voltage Rating (V) | Vibration | Nominal Melting I2T (A2sec) | Resistance (Ω) | Body | MSL | Opening | Operating Temperature | Agency Approvals |
---|
Part Number | Actions | Maximum AC Voltage (V) | Voltage Rating (V) | Vibration | Nominal Melting I2T (A2sec) | Resistance (Ω) | Body | MSL | Opening | Operating Temperature | Agency Approvals | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 0.21 | 1.19 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 0.76 | 0.497 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 2.01 | 0.28 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 7.6 | 0.0705 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 21 | 0.038 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 35 | 0.0187 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 54.8 | 0.0126 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 3.94 | 0.1151 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 13 | 0.0513 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 26.8 | 0.0233 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / METI | |||
125 | 125 | MIL-STD-202 Method 201 (10v55 Hz .06 in. total excursion) | 1.755 | Glass | MIL-STD-202 Method 106 High Humidity (90-98 RH) Heat (65&). | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR |
460 Applications
- Wireless basestation
- Network equipment
- Telecom equipment