HRV24AC
COIN COUNTER | Series: HRV
Operation
Coin Totalizer & Vending Timer (“S” Version):
Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time set on the upper 7 DIP switches begins. At the end of the vending time, the load de-energizes and the vending time is reset. Closing the initiate switch during vend timing will have no affect on vend time delay.
Accumulating Vending Timer (“A” Version):
Input voltage must be applied prior to & during operation. When the total number of S1 initiate switch closures equals the number to start set on the lower 3 DIP switches, the load energizes and the vending time starts. For every initiate switch closure, the HRV unit adds one time per coin period, as set on the upper 7 DIP switches, to the total vending time.
Operation Note: If S1 is closed when input voltage is applied, the output remains de-energized and the S1 counter remains at zero closures. At least one “vend time” and one “closures to start” DIP switch must be in the “ON” position for proper operation.
Reset: Removing input voltage resets the vend time delay, the S1 closure counter, and de-energizes the output relay.
Property | Value |
---|---|
Input Voltage (V) | 24 V ac |
Output Form | Isolated SPDT - NO |
Count Range | 1 - 7 counts to start; maximum: 250 |
Time Delay Range (s) | Adjustable 0.25 - 31.75 m |
Dimensions | 3 H x 2 W in. (76.7 x 51.3 mm) |
Adjustment | 7 of a 10 position DIP switch |
Circuitry | Encapsulated |
Counter Function Output | Mechanical (counts on switch closure) |
Humidity | 95% relative : non-condensing |
Input AC Line Frequency (Hz) | 50/60 |
Input Tolerance (%) | -15% - 20% |
Insulation Resistance (Ω) | ≥100 |
Isolation Voltage | ≥1500 Vrms input to output |
Life | Electrical: 1 x 10⁵ 3 x 104 for 1 hp - 6000 for 1/4 hp 1 hp and 2 hp; Mechanical: 1 x 10⁶ |
Mounting Method | Surface mount with 1 #10 (M5 x 0.8) screw |
Operating Temperature Max (°C) | 70 |
Operating Temperature Maximum Fahrenheit | 158 |
Operating Temperature Minimum Celsius | -40 |
Operating Temperature Minimum Fahrenheit | -40 |
Output Load Rating (VA) | General Purpose: SPDT-NO: 125/240 V ac ≅30 A; SPDT-NC ≅15 A; Resistive: SPDT-NO ≅30 A for 125/240 V ac and 20 A for 28 V dc; SPDT-NC ≅15 A for 125/240 V ac and 10 A for 28 V dc; Motor Load: SPDT-NO ≅1 hp for 125 V ac and 2 hp for 240 V ac; SPDT-NC ≅1/4 hp for 125 V ac and 1 hp for 240 V ac |
Output Type | Electromechanical relay |
Power Consumption | ≤4 VA |
Repeat Accuracy (%) | ±0.1% or 20 ms whichever is greater |
Reset Time (ms) | ≤150 |
Setpoint vs. Ambient Temperature and Operating Voltage | ≤±2% |
Setting Accuracy | 0% to 2% or 50 ms whichever is greater |
Storage Temperature Maximum Celsius | 85 |
Storage Temperature Maximum Fahrenheit | 185 |
Storage Temperature Minimum Celsius | -40 |
Storage Temperature Minimum Fahrenheit | -40 |
Surge Protection | IEEE C62.41-1991 Level A |
Switch Closure Time Minimum | ≥20 |
Switch Open Time Minimum | ≥20 |
Termination Type | 0.25 in. (6.35 mm) male quick connect terminals |
HRV24AC Resources
Part Number | Part Description | RoHS | Pb-Free | RoHS (2015/863/EU) Certificate | REACH (SVHC's) Declaration | REACH (SVHC's) | Halogen Free | IPC-Material Declaration | |
---|---|---|---|---|---|---|---|---|---|
HRV24AC | COIN COUNTER | View More |