Series: PHS
Littelfuse PHS Relays Provide Exceptional Phase Control Protection
The PHS Series Relays are designed for changing lamp intensity, varying the speed of a fan, or controlling the temperature of a heater. The effective output voltage is adjusted with an accessory external potentiometer suitable for line voltage applications.
Operation Upon application of input voltage, effective output voltage can be adjusted by changing the external resistance value. As the external resistance increases, the effective output voltage decreases, and the inverse is also true.
- External adjustment – potentiometer rated at 230 V ac
- Up to 20 A steady state – 200 A inrush
- Single hole surface mounting
- Solid-state design
- Allows direct control of heavy loads
- Allows direct control of heavy loads
- Provides quick and easy installation
- Longer life
PHS Parts
Filters
Showing 1 to 6 of 6 Total Results
Part Number | Actions | Input Voltage (V) | Termination Type | Mount Method | Dimensions | Weight (kg) | Dielectric Breakdown | Humidity | Input AC Line Frequency (Hz) | Input Tolerance (%) | Insulation Resistance (Ω) | Minimum Output Load Current (A) | Output Load Rating (VA) | Output Voltage Drop (V) | Storage temperature (°C) |
---|
Part Number | Actions | Input Voltage (V) | Termination Type | Mount Method | Dimensions | Weight (kg) | Dielectric Breakdown | Humidity | Input AC Line Frequency (Hz) | Input Tolerance (%) | Insulation Resistance (Ω) | Minimum Output Load Current (A) | Output Load Rating (VA) | Output Voltage Drop (V) | Storage temperature (°C) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
120 Vac | 0.25 in. (6.3 mm) male quick connect terminals | 2 H x 2 W x 1.51 D in. (50.8 x 50.8 x 38.4 mm) | 0 Kg (kilogram) | ≥2000 terminals to mounting surface | 95% non-condensing | 50 / 60 | ±20% | ≥100 | 100 | Steady state (100% on): 10 A; Inrush: 100 A | ≅2.0 at rated current | |||||
120 Vac | 0.25 in. (6.3 mm) male quick connect terminals | 2 H x 2 W x 1.51 D in. (50.8 x 50.8 x 38.4 mm) | 0 Kg (kilogram) | ≥2000 terminals to mounting surface | 95% non-condensing | 50 / 60 | ±20% | ≥100 | 100 | Steady state (100% on): 20 A; Inrush: 200 A | ≅2.0 at rated current | |||||
120 Vac | 0.25 in. (6.3 mm) male quick connect terminals | 2 H x 2 W x 1.51 D in. (50.8 x 50.8 x 38.4 mm) | 0 Kg (kilogram) | ≥2000 terminals to mounting surface | 95% non-condensing | 50 / 60 | ±20% | ≥100 | 100 | Steady state (100% on): 6 A; Inrush: 60 A | ≅2.0 at rated current | |||||
230 Vac | 0.25 in. (6.3 mm) male quick connect terminals | 2 H x 2 W x 1.51 D in. (50.8 x 50.8 x 38.4 mm) | 0 Kg (kilogram) | ≥2000 terminals to mounting surface | 95% non-condensing | 50 / 60 | ±20% | ≥100 | 100 | Steady state (100% on): 10 A; Inrush: 100 A | ≅2.0 at rated current | |||||
230 Vac | 0.25 in. (6.3 mm) male quick connect terminals | 2 H x 2 W x 1.51 D in. (50.8 x 50.8 x 38.4 mm) | 0 Kg (kilogram) | ≥2000 terminals to mounting surface | 95% non-condensing | 50 / 60 | ±20% | ≥100 | 100 | Steady state (100% on): 20 A; Inrush: 200 A | ≅2.0 at rated current | |||||
230 Vac | 0.25 in. (6.3 mm) male quick connect terminals | 2 H x 2 W x 1.51 D in. (50.8 x 50.8 x 38.4 mm) | 0 Kg (kilogram) | ≥2000 terminals to mounting surface | 95% non-condensing | 50 / 60 | ±20% | ≥100 | 100 | Steady state (100% on): 6 A; Inrush: 60 A | ≅2.0 at rated current |
PHS Applications
- Protection, control and/or monitoring of generators and other devices