The LCS10T12 connected to the LPM12 or LPMG12 indicator is a low cost, easy to use, go/no-go indication system for the remote monitoring of current flow. The LCS10T12 is installed on an adequately insulated wire of the monitored load. Its 12in. (30.4cm) leads are connected to the LPM12 or LPMG12 panel mount indicator directly or via customer supplied wires up to 500 feet (152.4m) long.


See datasheet to operation details.

PropertyValue
Termination Type
12 in. (30.4 cm) wire leads
Weight (kg)
0 Kg (kilogram)
DC Resistance (Ω)
65 Ω DC resistance of current limiter
Input AC Line Frequency (Hz)
50 / 60
Nominal Output Current Full Range
0 - 50
Sensor Frequency (Hz)
0 - 20 A: 20 - 100; 21-50A: 30-100
Sensor Hole Size
0.36 in. (9.14 mm) for up to #4 AWG (21.1 mm²) THHN wire
Sensor Monitored Current Range
2 - 50 A ac; Maximum: 50 A turns continuous; Inrush 300 A turns for 10 s
Operating Temperature Max (°C)
60
Operating Temperature Maximum Fahrenheit
140
Operating Temperature Minimum Celsius
-40
Operating Temperature Minimum Fahrenheit
-40
Storage Temperature Maximum Celsius
85
Storage Temperature Maximum Fahrenheit
185
Storage Temperature Minimum Celsius
-40
Storage Temperature Minimum Fahrenheit
-40