Series: 213
5x20mm Time Lag Surge Withstand Glass Body Cartridge Fuse Designed to IEC Specification
The 213 Series is a 5x20mm time-lag, surge-withstand, glass body cartridge fuse that is designed to IEC specifications.
- Conforms to EN/IEC/K/J 60127-1 and EN/IEC/K/J 60127-2
- Available in cartridge and axial lead form
- Meets the IEC 60127-2, Sheet 3 specification for time-Lag fuses
- RoHS compliant and lead-free
- Recognized to UL/CSA/NMX 248-1 and UL/CSA/NMX 248- 14
- Conforms to GB 9364.1 and GB 9364.2
- CE Mark indicates compliance with Low-Voltage and RoHS Directives.
213 Parts
Filters
Showing 1 to 12 of 16 Total Results
Part Number | Actions | Maximum AC Voltage (V) | Nominal Melting I2T (A2sec) | Resistance (Ω) | Opening | Operating Temperature | Agency Approvals |
---|
Part Number | Actions | Maximum AC Voltage (V) | Nominal Melting I2T (A2sec) | Resistance (Ω) | Opening | Operating Temperature | Agency Approvals | |
---|---|---|---|---|---|---|---|---|
250 | 0.225 | 1.6 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / BSI / CCC / VDE / CSA / Semko | |||
250 | 0.555 | 1.0495 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / CCC / BSI / CSA / Semko / UKCA / VDE | |||
250 | 202 | 0.02305 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / UKCA / CE / CCC / VDE / CSA / Semko / BSI | |||
250 | 1.36 | 0.535 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / BSI / UKCA / CCC / VDE / CSA / Semko | |||
250 | 2.905 | 0.37 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / CCC / VDE / BSI / CSA / Semko | |||
250 | 4.8 | 0.275 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / BSI / CCC / CSA / Semko / VDE | |||
250 | 9.42 | 0.1635 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / BSI / CCC / VDE / CSA / Semko | |||
250 | 27.15 | 0.08165 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / BSI / METI / CCC / VDE / CSA / Semko | |||
250 | 1.14 | 0.8475 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / BSI / CCC / Semko / UKCA / VDE / CE / CSA | |||
250 | 44.2 | 0.0551 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / BSI / METI / VDE / CCC / CSA / Semko | |||
250 | 138 | 0.03045 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / METI / BSI / CCC / VDE / CSA / Semko | |||
250 | 600 | 0.00951 | Slo-Blo/Time Lag (T)/Time Delay | -55° to 125°C | UR / CE / UKCA / BSI / CCC / METI / VDE / K / Semko / CSA |
213 Applications
- Used as supplementary protection in appliance or utilization equipment to provide individual protection for components or internal circuits.
Series: 213 Resources

Circuit Protection Selection Guide
Consult this guide to learn about circuit protection considerations and the solutions Littelfuse offers. Tables help match products with applications.