It's quick and easy to add multiple ZCASE® single bolt-down fuses to a post-style battery using the ZCASE® BMZ Series 32V Bolt-Down Battery-Mounted Fuse Holder. Available in 2-way and 3-way busbar configurations, the BMZ Series fuse holder features a compact design, so there's no need to wire in a separate fuse holder or power distribution module (PDM). Circuits can be added to the battery using wired ring terminals. Plus, thanks to the insulated bolts, there's no need for specialized nylon nuts. You can assemble the compatible ZCASE® single fuses (sold separately) using standard M8 threaded hardware (included in kits, not included with component parts).
- Works with ZCASE® single bolt-down fuses, allowing circuits to be added to a post-style battery using cables with wired ring terminals
- Battery terminal mount connects to either a 2-way or 3-way busbar and stud assembly, making it simple to mount multiple ZCASE® fuses to a battery post
- Insulated bolts eliminate the need for nylon nuts and allow fuse assembly with standard M8 threaded hardware included in kits
- Compact design eliminates the need to wire in a separate fuse holder or power distribution module
- Maximum total continuous current is 275 amps
ZCASE - BMZ Parts
Filters
Showing 1 to 7 of 7 Total Results
Part Number | Actions | Mounting Method | Fuse Type | Current Rating Max (A) | Current Rating (Continuous) in Amps | Voltage Rating (V) | Temperature Maximum (°F) | Temperature Minimum (°F) | Temperature Maximum (°C) | Temperature Minimum (°C) | Recommended Torque | Ignition protection | Input Terminals | Output Terminals |
---|
Part Number | Actions | Mounting Method | Fuse Type | Current Rating Max (A) | Current Rating (Continuous) in Amps | Voltage Rating (V) | Temperature Maximum (°F) | Temperature Minimum (°F) | Temperature Maximum (°C) | Temperature Minimum (°C) | Recommended Torque | Ignition protection | Input Terminals | Output Terminals | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
M8 Stud Mount - Battery terminal | ZCASE | 275 | 206 | 32 | 221 | -40 | 105 | -40 | 5.4 ± 0.9 Nm @ 540 RPM | V-0 | M6 Stud | M8 Stud Mount | |||
M8 Stud Mount - Battery terminal | ZCASE | 275 | 206 | 32 | 221 | -40 | 105 | -40 | 5.4 ± 0.9 Nm @ 540 RPM | V-0 | M6 Stud | M8 Stud Mount | |||
M8 Stud Mount - Battery terminal | ZCASE | 275 | 206 | 32 | 221 | -40 | 105 | -40 | 5.4 ± 0.9 Nm @ 540 RPM | V-0 | M6 Stud | M8 Stud | |||
M8 Stud Mount - Battery terminal | ZCASE | 275 | 206 | 32 | 257 | -40 | 125 | -40 | 5.4 ± 0.9 Nm @ 540 RPM | M6 Stud | |||||
M8 Stud Mount | ZCASE | 275 | 206 | 32 | 221 | -40 | 105 | -40 | 5.4 ± 0.9 Nm @ 540 RPM | M6 Stud | M8 Stud Mount | ||||
M8 Stud Mount | ZCASE | 275 | 206 | 32 | 221 | -40 | 125 | -40 | 5.4 ± 0.9 Nm @ 540 RPM | M6 Stud | M8 Stud Mount | ||||
ZCASE - BMZ Applications
- Starter Fusing